info@falconcables.in 011-47580222, 47590222

DIGITAL SNAKE CABLE





4 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.413 10.50
65(Cond.to.Cond) 91.12 TELEO70
190 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




8 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.551 14.00
65(Cond.to.Cond) 91.12 TELEO40
19 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




8 CHANNEL FLAT SNAKE CABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
27 AWG
0.041 1.05
100% A1.Foil+Dr
0.118 3.00
0.209x
1.130
5.30x
28.70
65(Cond.to.Cond) 164.88 TELEO83
10 X 0.120 BC PE Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




12 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.630 16.00
65(Cond.to.Cond) 91.12 TELEO43
19 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




16 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.748 19.00
65(Cond.to.Cond) 91.12 TELEO39
19 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




24 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.906 23.00
65(Cond.to.Cond) 91.12 TELEO44
19 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




32 DIGITAL CHANNEL SNAKECABLE ( RoHS ✓ )

AWG
Center
Conductor
NOM Insulation Dia.
Inches mm
Shield
Construction
(Min.)
NOM
One Channel Dia. Inches
mm
NOM
Jacket Dia.
Inches mm
NOM Capacitance
(Pf / mtr.)
Conductor Resistance Ohm / km
(Max.)
ITEM CODE
24 AWG
0.053 1.35
100%
0.130 3.30
0.984 25.00
65(Cond.to.Cond) 91.12 TELEO64
19 X 0.120 BC PE 56 X 0.102 BC Soft PVC Soft PVC 130(Cond.to.Shield) at 20°C


-Stranded Bare Copper Conductor -Soft PVC Jacketing -PE Insulation -99.99% Pure Copper




Contact Us

Incepted in 1985, Hitech Products Private Limited (Falcon Cables) is a self-motivated and quality-focused organization that is committed towards providing high grade electrical cables and wires.

Address

A- 13, B- 1 Extension, M. C. I. E., Badarpur, Mathura Road New Delhi - 110044, India